Optime IX Version History
Version 1.1 Build 4
Release Date: 12/22/09
- Modified the IXDLL to enable better use of the multi-connect capabilities of the hardware.
Version 1.1 Build 3
Release Date: 12/2/09
- Corrected a crash that could occur when rotating, inverting or flipping images during layout capture after the user clicked on the "Done" option.
Version 1.1 Build 2
Release Date: 9/14/09
- Corrected an issue with pressing the <Enter> key on the keyboard when capturing a progression. The progression acquisition would end and return to the main application WITHOUT displaying the images.
Version 1.1 Build 1
Release Date: 8/21/09
- Added new support for selected discipline in the invoking application.
- Added new support for general anatomy selection, veterinary anatomy and veterinary dental fields.
- Added CR modality support.
Version 1.0 Build 17
Release Date: 7/21/09
- Updated with the latest version of the GUI controls.
- Updated the image filter screen to delay the updates of the images while making changes to the filters. Added option to prevent auto-update all together. Added option to allow the user to update the image display manually.
- Corrected image rotation issue with continues endo series acqusitions.
Version 1.0 Build 14
Release Date: 3/3/09
- Updated with the latest version of the GUI controls.
- Corrected a memory leak that could potentially occur during progression acquisition.
- Updated file naming problems where '-' in the computer names were being replaced with '_'. This interfered with the calibration image capture storage and retrieval.
Version 1.0 Build 12
Release Date: 8/12/08
- Implemented new ghosting and retaken image classification. Additional options added to automatically mark images as ghosted or retaken based on the acquisition context.
Version 1.0 Build 11
Release Date: 4/9/08
- Due to a corruption in the Optime's 16-bit raw image data, the Optime extension now only works on 8-bit images even if the user selects 16-bits. The newer versions of the Optime imaging extension defaulted to 16-bits instead of 8-bit which resulted in problems during updates due to the periodic corruption of the image data returned from the Optime hardware.
Version 1.0 Build 10
Release Date: 4/8/08
- Image Operations popup menu on the progression screen now has an "Advanced Image Display" option. This option is the same as double-clicking on an image.
Version 1.0 Build 9
Release Date: 3/26/08
- Better image, series and study description labeling.
- Added new option to quickly edit image notes during progression capture.
Version 1.0 Build 8
Release Date: 2/2/08
- Updated the support of veterinary tooth display, tooth selection and information.
Version 1.0 Build 7
Release Date: 1/9/08
- Added new capabilities to display an advanced image display dialog when the user double-clicks on an image during progression capture.
Version 1.0 Build 6
Release Date: 12/21/07
- Recompile to include all new code changes (including vet and auto study and series descriptions).
Version 1.0 Build 5
Release Date: 4/4/07
- Corrected orientations when changing between various tiles when capturing a progression.
- Maintenance build.
Version 1.0 Build 4
Release Date: 2/27/07
- Image view control improved with additional funcationality: image enhancement drop-down (auto BC, emboss, invert); drag gamma adjustment tool added.
Version 1.0 Build 3
Release Date: 1/8/07
- Added popup that quickly allows the user to switch between multiple images that are associated with the same progression entry.
- Added image operations to the progression capture screen (e.g. Invert, flip, rotate).
- Display of a full screen image from the progression view now displays the image on a black background.
- Display a different cursor when the user moves the mouse over the multiple indicator when a progression entry contains more than one entry.
Version 1.0 Build 2
Release Date: 12/5/06
- Corrected values set for the Patient Orientation DICOM tag.